IVOA ObsCore

Coverage

How To Use This Target

Use native GMEOW terms as the authoring surface, then inspect the projection rows below to see which facts can leave GMEOW for this consumer vocabulary. Treat lossy notes as adoption warnings, not as implementation details.

Loss Notes

Profile Source Dropped Structure
ivoa gmeow:ScalarQuantity unit, determinacy, granularity, and reference frame are dropped; only the measured physical quantity survives
ivoa gmeow:Sensor the telescope/facility node is preserved, but agent roles and platform location are dropped
ivoa gmeow:Sensor the instrument node is preserved, but agent roles and platform location are dropped
ivoa gmeow:SensoryObservation determinacy, granularity, standpoint, and reference-frame metadata are dropped; only the generic dataset class survives
ivoa gmeow:SensoryObservation the full GMEOW reference-frame profile is flattened to a coordinate-system string or IRI
ivoa gmeow:SensoryObservation the telescope/facility node is preserved, but agent roles and platform location are dropped
ivoa gmeow:SensoryObservation the instrument node is preserved, but agent roles and platform location are dropped
ivoa gmeow:SensoryObservation unit, determinacy, granularity, and reference frame are dropped; only the measured physical quantity survives
ivoa gmeow:SensoryObservation the single GMEOW result node is replicated across all four ObsCore axes; axis-specific metadata (units, coverage, resolution) is not preserved
ivoa gmeow:hasReferenceFrame the full GMEOW reference-frame profile is flattened to a coordinate-system string or IRI
ivoa gmeow:observationResult unit, determinacy, granularity, and reference frame are dropped; only the measured physical quantity survives
ivoa gmeow:observationResult the single GMEOW result node is replicated across all four ObsCore axes; axis-specific metadata (units, coverage, resolution) is not preserved
ivoa gmeow:vantage the telescope/facility node is preserved, but agent roles and platform location are dropped
ivoa gmeow:vantage the instrument node is preserved, but agent roles and platform location are dropped

Source Terms

Term Label Slice
gmeow:ScalarQuantity Scalar Quantity observations
gmeow:Sensor Sensor sensory
gmeow:SensoryObservation Sensory Observation observations
gmeow:hasReferenceFrame has reference frame places
gmeow:observationResult observation result observations
gmeow:vantage vantage observations

Mapping Rows

Source Kind Profile Predicate/Relation Target Evidence
gmeow:ScalarQuantity equivalence - skos:relatedMatch obscore:observable gmeow-observations.sssom.tsv; gmeow:eqObs067; confidence 0.7
gmeow:Sensor equivalence - skos:relatedMatch obscore:facility gmeow-observations.sssom.tsv; gmeow:eqObs065; confidence 0.75
gmeow:Sensor equivalence - skos:relatedMatch obscore:instrument gmeow-observations.sssom.tsv; gmeow:eqObs066; confidence 0.75
gmeow:SensoryObservation equivalence - skos:closeMatch obscore:ObsDataset gmeow-observations.sssom.tsv; gmeow:eqObs063; confidence 0.85
gmeow:hasReferenceFrame equivalence - skos:relatedMatch obscore:coordsys gmeow-observations.sssom.tsv; gmeow:eqObs064; confidence 0.7
gmeow:ScalarQuantity projection ivoa projects to / <= obscore:observable gmeow:mapIvoaObservable; confidence 0.7; lossy: unit, determinacy, granularity, and reference frame are dropped; only the measured physical quantity survives
gmeow:Sensor projection ivoa projects to / <= obscore:facility gmeow:mapIvoaFacility; confidence 0.75; lossy: the telescope/facility node is preserved, but agent roles and platform location are dropped
gmeow:Sensor projection ivoa projects to / <= obscore:instrument gmeow:mapIvoaInstrument; confidence 0.75; lossy: the instrument node is preserved, but agent roles and platform location are dropped
gmeow:SensoryObservation projection ivoa projects to / <= obscore:ObsDataset gmeow:mapIvoaObsDataset; confidence 0.85; lossy: determinacy, granularity, standpoint, and reference-frame metadata are dropped; only the generic dataset class survives
gmeow:SensoryObservation projection ivoa projects to / <= obscore:coordsys gmeow:mapIvoaReferenceFrame; confidence 0.7; lossy: the full GMEOW reference-frame profile is flattened to a coordinate-system string or IRI
gmeow:SensoryObservation projection ivoa projects to / <= obscore:facility gmeow:mapIvoaFacility; confidence 0.75; lossy: the telescope/facility node is preserved, but agent roles and platform location are dropped
gmeow:SensoryObservation projection ivoa projects to / <= obscore:instrument gmeow:mapIvoaInstrument; confidence 0.75; lossy: the instrument node is preserved, but agent roles and platform location are dropped
gmeow:SensoryObservation projection ivoa projects to / <= obscore:observable gmeow:mapIvoaObservable; confidence 0.7; lossy: unit, determinacy, granularity, and reference frame are dropped; only the measured physical quantity survives
gmeow:SensoryObservation projection ivoa projects to / <= obscore:observableAxis, obscore:spatialAxis, obscore:spectralAxis, obscore:timeAxis gmeow:mapIvoaObsCoreAxes; confidence 0.65; lossy: the single GMEOW result node is replicated across all four ObsCore axes; axis-specific metadata (units, coverage, resolution) is not preserved
gmeow:hasReferenceFrame projection ivoa projects to / <= obscore:coordsys gmeow:mapIvoaReferenceFrame; confidence 0.7; lossy: the full GMEOW reference-frame profile is flattened to a coordinate-system string or IRI
gmeow:observationResult projection ivoa projects to / <= obscore:observable gmeow:mapIvoaObservable; confidence 0.7; lossy: unit, determinacy, granularity, and reference frame are dropped; only the measured physical quantity survives
gmeow:observationResult projection ivoa projects to / <= obscore:observableAxis, obscore:spatialAxis, obscore:spectralAxis, obscore:timeAxis gmeow:mapIvoaObsCoreAxes; confidence 0.65; lossy: the single GMEOW result node is replicated across all four ObsCore axes; axis-specific metadata (units, coverage, resolution) is not preserved
gmeow:vantage projection ivoa projects to / <= obscore:facility gmeow:mapIvoaFacility; confidence 0.75; lossy: the telescope/facility node is preserved, but agent roles and platform location are dropped
gmeow:vantage projection ivoa projects to / <= obscore:instrument gmeow:mapIvoaInstrument; confidence 0.75; lossy: the instrument node is preserved, but agent roles and platform location are dropped